Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.6930119

- Product Categories
- Friendly Links
Information Name: | Minimum film forming temperature tester |
Published: | 2012-02-15 |
Validity: | 30 |
Specifications: | |
Quantity: | 0.00 |
Price Description: | |
Detailed Product Description: | Specifications RefMFFT90 For water-based emulsion paint dry paint mandatory technical specifications and formulations, the minimum film forming temperature (MFFT) is very important. Subject of several designed using thermal gradient of the test method, but some methods have limited accuracy and reproducibility from very suspicious. A recommended test methods in ASTM (D2354) is described. SHEEN MFFT minimum film forming temperature in the tester, cooling and heating elements with nickel plated copper together, paying particular attention to ensure a good thermal coupling. This leads to the self-power is on, can rapidly respond to operational balance. Excellent insulation protection to ensure easy and stable operating conditions. ASTM D 2354/86 requested the test surface, there must be a constant current of clean, dry air through. Test proved that this uniform flow is the air conditioning unit within the enclosure (including the pressure regulator, filter, dry and flow controller included) to provide. Piped to the clean, dry air to the design of a sophisticated distribution system of porous sintered bronze, it will flow evenly distributed on the test surface. MFFT to test if applied to the sample surface over the same latex on the outcome when the article is consistent, it shows the final arrangement is to improve the flow right. One equipped with a hinged metal frame and transparent plastic cover, including the test board, insulation can also play a role. Old MFFT, there will be snow in the air at the entrance to the formation, SHEEN products designed to fully solve the problem. However, if the air dryer to break the circuit, or to open the cover, there will be snow-board test form, you will be easy to see that the cold frost line. In SHEEN FFT, in Vietnam 37mm intervals, the measurement accuracy of 0.1 degree temperature, the temperature of each point can be displayed, or you can switch to the differential mode, when the show will be around that point and its similar to the temperature difference between the two sensors, should be the same. We provide a probe capable of receiving input from the wander plug the holes. The probe is used to test the board that at the point of temperature, or used to test the calibration and temperature control MFFT. There are six process standard device hot side cold side cold side hot side -5 +13 +15 +18 +23 +50 +5 +33 -0 +23 +33 +60 If you need to provide additional high-temperature range of the hot end of the cold end +43 +70 +53 +80 +63 +90 allow the device to achieve a balance, you can use 1 inch, the film thickness of 75 microns cubic coating |
Admin>>>
You are the 58325 visitor
Copyright © GuangDong ICP No. 10089450, Shandong Ai to equipment All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 58325 visitor
Copyright © GuangDong ICP No. 10089450, Shandong Ai to equipment All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility